Key Account Sales
3-4 years of experience | Bachelor's degree | Marketing
Job Description:
1. Responsible for developing industry clients within the region;
2.Understand the customer's situation;
3.Understand the company's product characteristics, advantages, and comparison with competitors;
4.Provide corresponding products or solutions according to customer needs, meet customer needs, and solve customer problems;
5.Understand customer needs and provide improvement suggestions for the company's products;
6.Analyze sales data to increase market share of products in the responsible area;
7.Understand industry trends, peer information, technological changes and innovations;
Qualification:
1.College degree or above, majoring in biology, interested in sales position development, willing to accept fresh graduates;
2.Outstanding communication and learning abilities;
3.Priority given to those with industry work experience;
Recruitment email : xunliangsheng@t-sci.com
Contact Number : 021-57723582 Transfer to Human Resources Department
Contact person: Manager Xun
Regional Sales Manager
1-3 years of experience | associate degree | marketing
Job Description:
Responsible for channel management, customer development, market share enhancement, and brand image building within the region
Qualification:
1、College degree or above, strong learning ability, able to adapt to business trips
2、I have worked in the sales of laboratory consumables, reagents, instruments and other industries, and have strong self-management skills, a strong sense of responsibility, and a strong sense of teamwork
3、Strong interpersonal and communication skills, adept at identifying potential customer needs
Recruitment email : xunliangsheng@t-sci.com
Contact Number : 021-57723582 Transfer to Human Resources Department
Contact person: Manager Xun
Product manager
1-3 years of experience | Bachelor's degree | Marketing
Job Description:
1、Having an understanding and insight into the market, feedback market information to the marketing center and research and development center
2、Understand the entire process of company development and collect relevant product information
3、Understand the application, characteristics, advantages, and differences from competitors of the company's products
4、Provide product displays and introductions to customers, helping them solve pre-sales, in sales, and after-sales problems
5、Pay attention to the latest market trends, including competitor manufacturers, new products, and new technologies
6、Organize product related training materials and be responsible for training sales managers and customers
7、Visiting customers with sales managers, conducting technical exchanges and product demonstrations with customers
8、Participate in foreign exhibitions
Qualification:
1、Excellent expression ability
2、Priority given to those with excellent English proficiency
3、Willing to travel
4、Bachelor's degree or above in biology related majors
5、Individuals with relevant work experience in the vaccine industry
Recruitment email : xunliangsheng@t-sci.com
Contact Number : 021-57723582 Transfer to Human Resources Department
Contact person: Manager Xun
2024-11-19 09:00:08
Click:
作为一种高灵敏度、高精度的分析仪器,微量分光光度计在科学研究实验和工业检测领域发挥着至关重要的作用。在特定波长下,可对样品的吸光率或透光率进行定量分析,然后对样品中的化学成分或生物大分子浓度进行定量分析。但是,任何精密仪器的准确性都取决于定期的校准和维护,微量分光光度计也不例外。本文将探讨微量分光光度计的校准过程,包括校准的重要性、校准方法、常见问题及解决方案,为实验室工作人员提供详细的操作指南。
第一,校准的重要性
微分光度计的校准是保证测量结果准确可靠的基础。由于仪器磨损、光源老化、检测灵敏度变化和环境因素(如温度和湿度)的波动,对诚信和质量控制的重要组成部分进行了科学研究。为了保证实验数据的准确性和可重复性,定期校准可以及时发现和纠正这些偏差。
第二,校准前的准备工作
1. 环境控制:为了减少环境因素对校准结果的影响,确保校准操作在恒温、恒湿、无尘的环境中进行。
2. 仪器预热:根据仪器说明书的要求,提前打开仪器并进行预热,使仪器工作稳定。
3. 清洁保养:检查清洁光路系统、样品室、检测器等关键部件,确保无尘、指纹等污染物。
4. 标准准备:选择符合国家标准或行业标准的校准产品,确保其浓度准确、稳定。
第三,校准方法
微量分光光度计校准通常包括三个方面:波长精度校准、吸光精度校准和吸光范围校准。
1. 波长精度校准:利用已知波长的标准光源或滤光片,调整仪器的波长设置,通过测量实际输出波长与理论波长的区别,使其符合标准。
2. 吸光精度校准:在选定的波长下,用一系列已知浓度的标准溶液测量吸光值,并与理论值进行比较。为了调节仪器的增益或偏差,实际测量值应尽可能接近理论值。
3. 吸光范围校准:选择浓度范围广的一系列标准溶液,测量吸光值,绘制吸光浓度曲线。检查曲线是否接近直线,并计算线性相关系数。如果偏离线性,需要调整仪器参数或重新评估测量条件。
四,常见问题及解决方案
1. 波长偏移:可能是光源老化、光栅位置变化或波长校准器故障造成的。解决方案包括更换光源、调整光栅位置或校准波长校准器。
2. 吸光不稳定:可能是光源波动、检测器灵敏度变化或样品室污染造成的。如有必要,检查并稳定光源输出,清洁检测器和样品室,更换检测器。
3. 基线漂移:基线漂移是指仪器在零浓度或空白溶液下测量的非零吸收值。它可能是由光源老化、光路污染或电子系统噪声引起的。解决方案包括更换光源、清洁光路系统、调整电子系统参数等。
4. 测量结果重复性差:可能是样品处理不一致、仪器稳定性差或操作不规范造成的。确保样品处理标准化,稳定仪器工作状态,规范操作流程。
五、结论
微量分光光度计的校准与实验数据的准确性和可靠性直接相关,是一项复杂而精细的工作。通过科学的校准方法、严格的校准程序、及时的故障排除和解决策略,可以保证仪器始终处于最佳工作状态,为科研实验和工业检测提供坚实的技术保障。因此,实验室工作人员应高度重视仪器的校准,并将其视为实验成功和质量控制不可或缺的一部分。